Glossary
306 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Import a unit. Attach a set of disk drives with an existing configuration to
a controller and make the controller aware of the unit. Does not affect the
data on the drives.
Initialize. For 3ware SATA RAID controllers, initialize means to put the
redundant data on the drives of redundant units into a known state so that
data can be recovered in the event of a disk drive failure. For RAID 1 and
10, initialization copies the data from the lower port to the higher port.
For RAID 5, 6, and 50, initialization calculates the RAID 5 parity and
writes it to disk (background initialization). This is sometimes referred to
as resynching, and does not erase user data.
Note: If foreground
initialization is done before the operating system has loaded, zeroes are
written to all of the drives in the unit. This process, done through the
3ware BIOS, does erase existing data.
Logical Units. This term is used in the 3ware CLI. It is usually shortened
to “units.” These are block devices presented to the operating system. A
logical unit can be a one-tier, two-tier, or three-tier arrangement. Single
logical units are examples of one-tier units. RAID 1, RAID 5, and RAID
6 are examples of two-tier units and as such will have sub-units. RAID 10
and RAID 50 are examples of three-tier units and as such will have sub-
sub-units.
JBOD. An unconfigured single drive. The acronym is derived from “just
a bunch of disks.” Note that earlier versions of the 3ware RAID controller
exported JBODs to the OS. This is no longer supported. Individual drives
should be configured as Single Disks in order to be made available to the
OS.
Migration. The process of changing the characteristics of a unit. The
change can be to expand the capacity of the unit (OCE), change the stripe
size of the unit, change the unit from redundant to non-redundant, change
the unit from non-redundant to redundant, and to change the unit from
one type of redundant unit to another type of redundant unit (for example
RAID 1 to RAID 5).
Mirrored disk array (unit). A pair of drives on which the same data is
written, so that each provides a backup for the other. If one drive fails, the
data is preserved on the paired drive. Mirrored disk units include RAID 1
and RAID 10.
NCQ (Native Command Queuing). See “Queuing”
Non-redundant units. A disk array (unit) without fault tolerance
(RAID 0 or single disk.).
OCE (Online Capacity Expansion). The process of increasing the size of
an existing RAID unit without having to create a new unit. See also
migration.
Parity. Information that the controller calculates using an exclusive OR
(XOR) algorithm and writes to the disk drives in RAID 5, RAID 6, and
Vista de página 317
1 2 ... 313 314 315 316 317 318 319 320 321 322 323 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema