LSI 3ware SAS 9750-8i Guia do Utilizador Página 285

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 284
Error and Notification Messages
www.lsi.com/channel/products 273
Cause
The controller has detected and corrected a memory ECC error.
Action
None required.
If errors persist, contact technical support at
http://www.lsi.com/channel/ContactUs
.
003A Drive power on reset detected
Event Type
Error
Cause
The controller has detected that a drive has lost power and then restarted. The
controller may degrade the unit if it is a redundant unit (non-redundant units
cannot be degraded).
Action
If this drive was the only one to lose power, check the cable connections.
Also, check that your power supply is adequate for the type and number of
devices attached to it.
See Also
For troubleshooting information and a link to drive manufacturer diagnostic
utilities, search the LSI Knowledge Base for keyword 14927 (use the
Advanced Search) at
https://selfservice.lsi.com/service/main.jsp
003B Rebuild paused
Event Type
Information
Cause
The rebuild operation is paused.
Rebuilds are normally paused for two (formerly ten) minutes after a system
first boots up and during non-scheduled times when scheduling is enabled.
Disabling or modifying the schedule with 3DM 2 or CLI will allow the
rebuild to resume.
Vista de página 284
1 2 ... 280 281 282 283 284 285 286 287 288 289 290 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema