LSI 3ware SAS 9750-8i Guia do Utilizador Página 278

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 277
Troubleshooting
266 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Action
When a verify fails, redundant units will automatically resynchronize user
data through a background initialization. The initialize will not erase user
data, but will recalculate and rewrite user parity data.
If the unit was non-redundant, any data in the error location is lost. (However,
the error could be in a part of the drive that did not contain data.) A unit file
system check is recommended.
Under Windows, right-click on your drive icon and choose
Properties>
Tools> Check Now
.
Under Linux use
fsck /dev/sda1. If you have more than one SATA device,
substitute the correct drive letter and partition number, such as sdb2, for sda1.
The resynchronization of data that takes place during a background
initialization can slow down access to the unit. Once initialization has begun,
it cannot be canceled. You can pause it, however, by scheduling it to take
place during off-hours. For more information, see “Scheduling Background
Tasks” on page 169. You can also set the initialization process to go slower
and use fewer system resources. For more information, see “Setting
Background Task Rate” on page 168. (Initialization occurs at the Rebuild
rate.)
See Also
“About Initialization” on page 152
002B Verify completed
Event Type
Information
Cause
Verification of the data integrity of a unit was completed successfully.
See Also
“About Verification” on page 155
Vista de página 277
1 2 ... 273 274 275 276 277 278 279 280 281 282 283 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema