Troubleshooting
286 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
This message is posted when the result of the health test is below the warning
threshold.
Action
Replace the battery pack if warnings persist.
005E Cache synchronization completed
Event Type
Information
Cause
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. This message is posted for each
unit when the cache synchronization completes successfully.
You will also see this message if drive insertion causes a unit to become
operational and retained write cache data was flushed.
005F Cache synchronization failed; some data lost
Event Type
Error
Cause
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. The cache synchronization was
not successful for some reason.
0062 Enclosure removed
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
An enclosure is no longer accessible to the RAID controller. The likely cause
is that the enclosure has been powered down or that a cable has been
unplugged.