Troubleshooting
260 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Action
The unit is no longer available for use. Return all missing drives to the unit. If
the drives are physically present, check all data and power connections.
CAUTION: Do not delete the inoperable unit and recreate it as this will
overwrite the data and make data recovery very difficult.
You may wish to contact technical support at
http://www.lsi.com/channel/ContactUs.
See Also
“About Inoperable Units” on page 145
001F Unit Operational
Event Type
Information
Cause
Drive insertion caused a unit that was inoperable to become operational again.
Any data that was on that unit will still be there. This message is only sent if
the unit was inoperable for more than 20 seconds. That means that if the hot
swap of a drive occurred within 20 seconds, messages are not generated.
Action
None Required. The unit is available for use.
0021 Downgrade UDMA mode
Event Type
Warning
Cause
The 3ware RAID controller has downgraded the UDMA transfer rate between
the controller and the ATA disk drives. This message only applies to parallel
ATA and certain legacy serial ATA drives.
Background Information
The 3ware RAID controller communicates to the ATA disk drives through the
Ultra DMA (UDMA) protocol. This protocol ensures data integrity across the
ATA cable by appending a Cyclical Redundancy Check (CRC) for all ATA
data that is transferred. If the data becomes corrupted between the drive and