Background Tasks
www.lsi.com/channel/products 153
Although you can use the unit while it is being initialized in the background,
initialization does slow I/O performance until completed. You can adjust how
much initialization will slow performance by setting the rate at which it
occurs. (See “Setting Background Task Rate” on page 168.) You can also
postpone initialization until a scheduled time. (See “Scheduling Background
Tasks” on page 169).
Initialization of Different RAID Types
Information about initialization for each of the different RAID types is
described below and summarized in Table 12 on page 154.
Initialization of RAID 0 Units
RAID 0 units do not need to be initialized and cannot be initialized. RAID 0
units are immediately available for use with full performance when created.
Initialization of RAID 5, RAID 6, and RAID 50 Units
RAID 5 units with three or four drives will be automatically initialized the
first time they are verified.
Regardless of the size, all 9000-series RAID 5, RAID 6, and RAID 50 units
are fully fault tolerant upon creation. These configurations use a specialized
scheme for writing to the unit, which does not have to be valid to provide fault
tolerance.
Performance of the following types of units will improve after the unit has
been initialized: RAID 6, RAID 5 units with 5 or more disks, and RAID 50
units with 2 subunits of 5 or 6 disks. For these configurations, initialization
begins automatically after you create them. If you create them in 3BM using
the default foreground initialization method, zeroes are written to all unit
members before booting to the operating system. If you create them through
3DM, you will boot to the operating system and the RAID 5 parity is then
calculated and written to disk, keeping any data in the unit intact.
RAID 5 units with 3 or 4 disks do not need to be initialized to have full
performance upon creation. It is okay that 3 or 4 disk RAID 5 units are not
initialized. These RAID types are fully redundant, regardless of whether or
not they are initialized. Similarly, RAID 50 units with a grouping of 3 or 4
disks in a subunit do not need to be initialized. However, RAID 50 with a
Note: Units that do not need to be immediately initialized for full performance will
be automatically initialized using background initialization when they are verified for
the first time. (Verification requires that the units have been previously initialized.)
This will not affect the data on the drives, and the units will perform normally,
although performance will be slowed until the initialization and verification are
completed.
Vista de página 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema