Error and Notification Messages
www.lsi.com/channel/products 253
the rebuild. However, because ATA drives can reallocate sectors on write
errors, the rebuild failure is most likely caused by the source drive of the
rebuild detecting a read error.
Action
The default operation of the 3ware RAID controller is to abort a rebuild if an
error is encountered. If you want rebuilds to continue when there is a source
error, you can set a unit policy to Continue on Source Error When Rebuilding
in 3DM 2 or CLI.
The consequence of continuing a rebuild when there is a source error is that
there may be corrupt data in your rebuilt unit. In some cases, however, this
may be your only alternative for recovering as much data as possible from a
unit that has become degraded.
To lower the likelihood of getting this error, schedule regular verifications.
See Also
“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” on
page 116.
“Scheduling Background Tasks” on page 169
0005 Rebuild completed
Event Type
Information
Cause
The 3ware RAID controller has successfully completed a rebuild. The data is
now redundant.
Action
None required.
0006 Incomplete unit detected
Event Type
Warning
Cause
The 3ware RAID controller has detected an incomplete unit.
Vista de página 264
1 2 ... 260 261 262 263 264 265 266 267 268 269 270 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema