LSI 3ware SAS 9750-8i Guia do Utilizador Página 280

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 279
Troubleshooting
268 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Under Linux use fsck /dev/sda1. If you have more than one SATA device,
substitute the correct drive letter and partition number, such as sdb2, for sda1.
See Also
“Starting a Verify Manually” on page 158
“Enabling or Disabling Auto Verify for a Unit” on page 115
“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” on
page 116
002E Replacement drive capacity too small
Event Type
Error
Cause
The storage capacity of the drive you are using as a replacement drive is too
small and cannot be used.
Action
Use a replacement drive equal to or larger than the drives already in use
002F Verify not started; unit never initialized
Event Type
Warning
Cause
A verify operation has been attempted by the 3ware RAID controller, but the
unit has never been initialized before. The unit will automatically transition to
initializing mode and then start a verify.
Action
None required.
This is considered a normal part of operation. Not all types of RAID units
need to be initialized in order to have full performance. The initialize will not
erase user data, but will calculate and write parity data or mirror data to the
drives in the unit.
Vista de página 279
1 2 ... 275 276 277 278 279 280 281 282 283 284 285 ... 341 342

Comentários a estes Manuais

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema