Error and Notification Messages
www.lsi.com/channel/products 285
Cause
The measured capacity of the battery is below the error level. The Battery
Backup Unit is not ready and is unable to backup the 3ware RAID controller.
Action
Replace the battery pack.
See Also
See the Install Guide for your controller.
005A Battery is present
Event Type
Information
Cause
A battery pack is connected to the 3ware RAID controller.
005B Battery is not present
Event Type
Error
Cause
The battery pack has been removed from the 3ware RAID controller.
Action
Reinstall the battery pack.
005C Battery is weak
Event Type
Warning
Cause
The Battery Backup Unit periodically evaluates the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.