LSI 9690SA-8E-KIT Guia de Instalação Página 117

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 138
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 116
Enclosure Object and Element Commands
www.lsi.com/channel/products 109
Enclosure Object and Element Commands
Enclosure object commands provide information and perform actions related
to a specific enclosure, such as /c0/e0 and its elements, for example, /c0/e0/
slot0. Enclosure object elements include slot, fan, temperature sensor, power
supply, and alarm elements.
The following table summarizes the supported controllers, protocols, configurations,
and enclosure elements.
Syntax
/cx/ex show
/cx/ex show attribute [attribute ...] where attributes are:
controllers|diag|protocol|slots|fans|temp|pwrs|alarms
/cx/ex show all
/cx/ex/slotx show
/cx/ex/slotx show identify
/cx/ex/slotx set identify=on|off
/cx/ex/fanx show
/cx/ex/fanx show identify
Note: The command descriptions of this section show the syntax of enclosure
commands for 9750 and 9690SA controllers, which specify the controller ID and the
enclosure ID. For the 9650SE, simply drop the prepended controller name in the
command. For example, use
/e0 instead of /c1/e0.
Table 11: Enclosure protocol, syntax, and supported elements
Controller 9650SE
9750 and
9690SA
Configuration/Protocol CCU/SAF-TE
SES I
2
C
backplanes
SES-2
Syntax /ex /ex /cx/ex
Enclosure
Element
Supported
Slot Y Y Y
Fan Y Y Y
Temperature
Sensor
YYY
Power Supply N Y Y
Alarm N Y Y
Vista de página 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 137 138

Comentários a estes Manuais